The cable manufacturer SAB Bröckskes presents a new marine cable on the market. According to the manufacturer it is a DNV-GL approved reeling cable – DR 750 P Offshore
for the application on ships and for offshore use.
The robust construction with reference to the international standard IEC 60092 for ship cables is appropriate for reeling applications with high mechanical stress. The DNV-GL approval as well as the excellent mechanical characteristics offer highest reliability in application.
Outstanding characteristics of the cable are
- flame retardant and self-extinguishing
- halogen free acc. to IEC 60754-1
- oil and chemical resistant
- MUD resistant
- weather resistant
- reduced outer diameter
- low cable weight
- suitable for winding stress at low temperatures
- high reeling and unreeling strength
- DNV-GL certificate-no. TAE 0000002
Application fields
Possible application fields of the DR 750 P Offshore are offshore cranes, deck machines, working platforms, lifts, lifting and conveyor technique on ships and offshore facilities.
The SAB cable could already prove itself in practise with extreme environmental conditions. Due to its oil and chemical resistance this robust cable has already been used for example in engine operated rail bound transport vehicles on oil producing ships.
Not at least due to the prevailing extreme environmental and weather conditions in its worldwide application, the DR 750 P offshore is especially appropriate because of the
extremely robust construction.
Especially in a temperature range from -40°C…up to + 60°C under dry and damp climatic conditions, the cable can be used for many marine applications.
Special solutions for special applications
The production possibilities of SAB do not only cover the basic type and standard dimensions but also special cables which are designed according the individual requirements of the customer.
Cable manufacturer – SAB Bröckskes is a worldwide leading manufacturer of cables and wires, cable harnessing and temperature measuring technique. More than 60 years of experience in cable manufacturing as well as in temperature measuring technique have made out of a one man business a company with almost 500 staff members.
The strength of SAB Bröckskes is not only the manufacturing of standard cables but also the construction of special items. Every year SAB manufactures more than 1500 special cables on customer´s request.
Firmenkontakt und Herausgeber der Meldung:
SAB Bröckskes GmbH & Co. KG
Grefrather Str. 204-212b
41749 Viersen
Telefon: +49 (2162) 898-0
Telefax: +49 (2162) 898-101
http://www.sab-broeckskes.de